75 GPD RO Membrane — 1812 TFC
This page covers which systems the membrane fits, how to replace it step by step, when to change it, and what to do if something doesn’t look right.

Check these against the membrane in your hand.
- ✓A blue membrane about 12″ long and 1.8″ across
- ✓A black rubber brine seal at one end and two O-rings on the center tube at the other
- ✓The label says Model TW-1812-75 and My Water Club
- 75 GPD — this membrane. The usual rating for under-sink RO systems with a storage tank.
- 100 GPD and higher — fit the same 1812 housing and make more water per hour. All RO membranes →
- Changing the rating? The small flow restrictor on the drain line is matched to the membrane rating. Same rating, no change needed; a different rating may need a matching restrictor — ask us.
Specifications
| Model / SKU | TW-1812-75 |
| Type | Thin-film composite (TFC), tap-water (TW) low-pressure membrane |
| Rating | 75 GPD — about 3.1 gal/hr (rated at about 77°F, 60 PSI and low-TDS water; real output is usually lower) |
| Size | 1812 (1.8″ × 12″) · fits standard 1812 housings; MyWaterClub housings also accept 2012 |
| Seals | Brine seal and double O-rings pre-installed |
| Typical life | 2–3 years with good pre-filtration |
| Needs | Sediment and carbon pre-filters before it; chlorine must be removed before the membrane |
| Brand | MyWaterClub |
Reorder this membrane
The same membrane you have now.
Where this membrane is used
| System | Where the membrane sits | Notes |
|---|---|---|
| Under-sink RO 4- or 5-stage, with tank |
Stage 4: after the sediment and two carbon pre-filters, in the horizontal membrane housing | The most common use. Fits systems built around a standard 1812 75 GPD membrane. |
| MyWaterClub countertop RO | The membrane housing after the pre-filters | Our countertop housings accept 1812 and 2012 membranes. A 75 GPD membrane fits and makes a little less water per hour than the 100 GPD our systems usually ship with. |
| Other RO systems | Any standard 1812 membrane housing | Not for tankless or capsule-style systems that use their own built-in membrane. |
- iSpring MC7 — RCC7 series under-sink systems (RCC7, RCC7AK, RCC7P)
- APEC MEM-ES-75 — Essence ROES-PH75 and ROES-UV75
- TW30-1812-75 and other standard 1812 75 GPD membranes
Brand names are used only to show compatibility. MyWaterClub is not affiliated with these companies. Not sure? Send us a photo of your old membrane and housing.
How to replace the membrane
The housing cap unscrews; the membrane slides out.
The O-ring end goes in first. The brine seal end faces the cap.- You need: the new membrane, a towel, pliers to pull the old membrane, and a housing wrench if the cap is tight.
- Good time to change the sediment and carbon pre-filters too — they protect the new membrane.
- Keep the new membrane sealed in its bag until you are ready. Wash your hands first.
- Shut off the water. Close the feed valve to the RO system (and the tank valve on an under-sink system), then open the RO faucet to release pressure.
- Open the housing. If a tube connects to the cap, press the collet ring and pull the tube out. Unscrew the cap by hand or with the housing wrench.
- Pull out the old membrane with pliers by the center tube. Note which way it came out.
- Wet the O-rings on the new membrane with clean water so they slide in. Do not use petroleum grease.
- Push the new membrane in, double-O-ring end first, until it seats firmly. The brine seal end faces the cap. It takes a firm push — the end should sit flush, not stick out.
- Check the cap O-ring, screw the cap on hand-tight (snug with the wrench if needed) and reconnect any tube.
- Turn the water back on and check for leaks now, after 10 minutes and the next day.
- Flush before drinking: let the tank fill and drain it completely twice (discard the first two full tanks). On a countertop system, discard the first two full tanks of purified water.
- Write the date on the membrane housing or in your system manual.
First time? Search YouTube for “replace RO membrane under sink” — a short video makes the steps easy to follow. Countertop owners: follow your system’s manual for opening the cabinet.
Checking it with a TDS meter
- Wait one week after the change. New filters and a new membrane read high for the first days.
- Measure your tap water and the RO water the same day. Reduction = (tap − RO) ÷ tap. A healthy membrane typically reduces 95–99%.
- Measure right after the membrane if you have a remineralization or alkaline stage — those add minerals on purpose and raise the reading.
When to change your membrane
| Component | Typical interval | Change sooner if… |
|---|---|---|
| RO membrane | 2–3 years | TDS reduction drops below about 85–90%, or output stays slow after fresh pre-filters |
| Sediment and carbon pre-filters | 6–12 months | Output slows, or chlorine taste comes back |
Changing the pre-filters on time is the best way to make a membrane last.
Common questions
| What you’re seeing | Most likely cause |
|---|---|
| Slow water production | Clogged pre-filters, low water pressure (under about 40 PSI) or very cold water. Change the pre-filters first. |
| TDS high right after the change | Normal for the first days. Flush two tanks and test again after a week. |
| Leak at the housing cap | Cap O-ring twisted, dry or out of its groove. Release pressure, reseat it and re-tighten. |
| Membrane won’t go all the way in | Wet the O-rings and push straight and firmly. Make sure the O-ring end goes in first. |
| Water runs to the drain all the time | Normal while the tank fills. If it never stops, the shut-off valve or check valve may need service — contact us. |
| Water tastes flat | RO removes most minerals. A remineralization filter after the membrane adds some back. |
Related parts
| Part | Notes |
|---|---|
| RO membranes | Other ratings that fit the same housing |
| Carbon post filter (PAC-QC) | Final taste polish after the membrane |
| Inline filter guide | Remineralization, alkaline and other add-on stages |
Need help?