5 Micron Sediment Filter — 20″ × 4.5″
How to identify this cartridge, when to change it, how to change it, and how to get the exact replacement.
Check the cartridge in your housing against this list.
- ✓A large cartridge, about 4.5″ wide and 20″ long
- ✓White, fibrous melt-blown surface — no pleats
- ✓Label reads SED5-20BB · 5 micron
- ✓Sits in the first housing that water enters
This page is for the 20″-long cartridge. Measure the cartridge (or the housing body): a 20″ cartridge won’t fit a 10″ housing, and a 10″ cartridge won’t seal in a 20″ one. Have the 10″ × 4.5″ size? See SED5-10BB support →
Online ordering for SED5-20BB is coming soon to MyWaterClub.com. Until then, call or message us with the SKU and we’ll help you get the right cartridge.
Specifications
| SKU | SED5-20BB |
| Type | Melt-blown polypropylene sediment cartridge |
| Fits | Standard 20″ × 4.5″ heavy-duty whole-house housings |
| Micron rating | 5 micron (nominal) |
| Position | Stage 1 — always first in line |
| Typical life | 6–9 months |
| Water | Cold water only, 40–100 °F |
| Brand | My Water Club |
When to change it
| Part | Typical interval | Change sooner if… |
|---|---|---|
| This cartridge | 6–9 months | Whole-house pressure drops · cartridge turns dark brown or orange · well water or after plumbing work |
| Housing O-rings | Check at every change · replace every 12–24 months | Flattened, cracked, hard, or weeping at the seam |
Good to know
- A brown cartridge is a working cartridge. The color is dirt it caught. Change it by pressure and appearance, not by the calendar alone.
- Heavy sediment or well water? The washable pleated SED5-PLT-20BB can be rinsed and reused instead of replaced.
- It doesn’t reduce chlorine or taste. That’s the carbon stage’s job — the sediment stage catches grit before it reaches the carbon.
How to change the cartridge
- Close the valves on both sides of the system (or the main house shut-off). Put a bucket under the housing — a 20″ sump holds about twice the water of a 10″.
- Press the pressure release button on top of the cap until the hissing stops.
- Loosen the sump with the heavy-duty housing wrench. Looking up at the bottom of the sump, turn it counterclockwise. Support it with both hands as it comes free — a full 20″ sump is heavy.
- Lift out the old cartridge, empty the sump and rinse it out. Wipe the O-ring grooves clean.
- Check both O-rings. Replace them if they’re flattened, cracked or hard. Coat them lightly with food-grade silicone grease (never petroleum jelly) and seat them without twists.
- Remove the new cartridge’s plastic wrap and stand it in the sump, centered on the post at the bottom.
- Screw the sump back on by hand until snug, then add up to a quarter turn with the wrench. Don’t overtighten — that crushes the O-ring and stresses the cap.
- Open the inlet valve slowly. Press the release button again to let trapped air out, check the seam for drips, then open the outlet valve.
- Run a cold tap for 2–3 minutes to flush the new cartridge.
- Write the date on the cartridge label, so the next change is easy to time.
Housings sit under line pressure every day, and the plastic slowly fatigues. Replace the housing about every 5 years, or right away at any crack, crazing or leak that new O-rings don’t fix. Keep the system indoors, out of direct sun, and protected from freezing. If your water pressure is above 80 PSI, fit a pressure regulator or pressure limiting valve ahead of the system.
Troubleshooting
| Problem | Likely cause | What to do |
|---|---|---|
| Drip or weep at the sump seam | O-ring twisted, dirty, dry or worn | Depressurize, clean the groove, regrease or replace the O-rings (O-ring sets). Hand-tight plus a quarter turn is enough. |
| Low water pressure in the whole house | Clogged cartridge — usually the sediment stage | Change the cartridge. If pressure drops quickly every time, your water carries heavy sediment — change sooner, or use the washable pleated cartridge in Stage 1. |
| Sump won’t unscrew | Over-tightened, or still under pressure | Close the valves and press the release button first. Use the housing wrench, turning counterclockwise as seen from below. Grease the O-rings at reassembly so it opens easily next time. |
| Crack, crazing or a leak from the housing body | Housing at end of life, frozen, or over-pressured | Shut off the water. Don’t keep using a cracked housing — replace it (ask us which one fits). |
Parts for your housing
Not sure which cartridge you have, or which one fits? Send a photo of the cartridge label or the housing to My Water Club support, or call (858) 345-7345, and we’ll tell you exactly what to order.