Description
The PureT TFCWT-18116-50 is a 50 GPD thin-film composite (TFC) reverse osmosis membrane made for Watts Premier standard RO systems. Watts Premier uses a reverse-seal membrane that standard 1812 membranes don’t fit. This membrane is built to the Watts size and seal layout, so it drops straight into your existing housing and restores full output and rejection.
What this membrane does
The membrane is the heart of a reverse osmosis system. Water is pushed through a semi-permeable thin-film layer that lets water molecules pass and sends dissolved solids, salts and metals to the drain. The pre-filters before it remove sediment and chlorine; the post-filter after it polishes taste. Over 2–3 years the membrane slowly loses output and rejection, and replacing it brings the system back to like-new performance.
Key benefits
- Built to Watts Premier dimensions and reverse-seal layout, so no water bypasses the membrane
- 50 GPD output, about twice the water of the original 24 GPD membrane
- Thin-film composite membrane material made in USA
- Factory-sealed and dry-packed for long shelf life
- Drop-in replacement, no tools or plumbing changes
- Costs less than the OEM Watts membrane
Specifications
| Attribute | Value |
|---|---|
| Model | PureT TFCWT-18116-50 |
| SKU | MEM-1812-50-WP |
| Rated output | 50 GPD (~2.1 gal/hr)* |
| Membrane type | Polyamide thin-film composite (TFC) |
| Water type | Tap water (municipal or well) |
| Size | 1.8″ × 11-5/8″ |
| Seal design | Watts Premier reverse seal |
| Replacement interval | 2–3 years, or when product-water TDS rises |
| Pre-treatment | Sediment and carbon pre-filters required (chlorine removal) |
| Compatible with | Watts Premier WP-4V, WP-5, RO-TFM-4SV, RO-TFM-5SV, ZRO-4† |
What a TFC membrane helps reduce
| Category | Examples | Average reduction* |
|---|---|---|
| Total Dissolved Solids | Overall TDS reading | 90–98% |
| Fluoride | Fluoride | 85–95% |
| Heavy metals | Lead, copper, chromium, cadmium | 90–98% |
| Nitrates/nitrites | Nitrate, nitrite | 80–95% |
| Dissolved salts and minerals | Sodium, calcium, sulfate, chloride | 90–98% |
*Typical ranges for residential TFC membranes. Not a certified claim for each unit. Actual results depend on water pressure, temperature, TDS and pre-filter condition.
About bacteria and microorganisms: this membrane is not sold as a microbiological purifier. Do not use it with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Which membrane do I need?
| Your system | Size | Output | Membrane |
|---|---|---|---|
| Watts Premier WP-4V, WP-5, RO-TFM, ZRO-4 | 1.8″ × 11-5/8″ | ~2.1 gal/hr | MEM-1812-50-WP (this membrane) |
| Standard under-sink RO, 1812 housing | 1812 | ~2.1 gal/hr | MEM-1812-50-U or TW-1812-50 |
| RainSoft UF50T / UF50N | 1.8″ × 10″ | ~2.1 gal/hr | MEM-1810-50-RS |
| Kenmore with 10″ membrane | 1.8″ × 10″ | ~2.1 gal/hr | MEM-1810-50-KM |
| Culligan AC-30 / AC-15 | 1.85″ × 12″ | ~2.1 gal/hr | MEM-1812-50-CU |
Good to know before you buy
What “50 GPD” means. 50 gallons per day is the lab rating at standard test conditions, about 2.1 gallons per hour. At typical home pressure and cooler water, expect less.*
Upgrading from 24 GPD (560014)? The drain-line flow restrictor must match the membrane. If yours is rated for 24 GPD, replace it with a 50 GPD restrictor. If your system already uses the 50 GPD 560018 membrane, no change is needed.
Pre-filters protect the membrane. Chlorine destroys TFC membranes. Replace your sediment and carbon pre-filters on schedule, ideally at the same time as the membrane.
Replacing your membrane
- Turn off the cold-water feed to the RO system and close the tank valve.
- Open the RO faucet to release pressure.
- Disconnect the tubing from the membrane housing cap and unscrew the cap.
- Pull out the old membrane, using pliers if needed. Note which way it faces.
- Insert the new membrane in the same direction and push it firmly into place.
- Replace the cap and tubing, turn the water back on, and check for leaks.
- Let the tank fill, then drain it completely. Repeat once and discard the first two tanks.
Compatible systems & replacement membranes
RO systems it fits†
| Watts Premier system | Model number |
|---|---|
| WP-4V | 500109 |
| WP-5 | 500023 |
| RO-TFM-4SV | 500025 |
| RO-TFM-5SV | 500032 |
| ZRO-4 | 500029 |
Replaces these membranes†
| Watts Premier membrane | Output |
|---|---|
| 560014 (WP560014) | 24 GPD |
| 560018 (110019, 110010, F560018) | 50 GPD |
Check before you order: your old membrane should be about 1.8″ × 11-5/8″ and labeled Watts Premier. A standard 12″ membrane from another brand means your system takes a standard 1812 membrane, not this one.
Fit questions
Will it replace the Watts Premier 560014?
Yes. It fits the same housing; switch the drain flow restrictor to 50 GPD (see above).
Will it replace the 560018?
Yes, like for like at 50 GPD.
Does it fit the Watts Premier system sold at Costco?
The Costco Premier RO system (item 572035) uses the 560014 membrane, so yes, with the 50 GPD flow restrictor.
Will it fit a standard (non-Watts) RO system?
No. Standard systems need a standard 1812 membrane such as MEM-1812-50-U.
Does it come with a flow restrictor?
No, the membrane only.
*Rated output, reduction ranges and compatibility are based on manufacturer and industry data; real-world output is usually lower than the rating.
†Watts and Watts Premier are trademarks of Watts Water Technologies. My Water Club is not affiliated with or endorsed by Watts. This is a compatible replacement membrane, not an OEM Watts part.



Reviews
There are no reviews yet.