The Ovay OV-ULP1812-50 is a 50 GPD ultra-low-pressure (ULP) thin-film composite reverse osmosis membrane in the standard 1.8″ × 12″ (1812) size. It drops into the membrane housing of most 4- and 5-stage under-sink RO systems. The ULP design is built to keep producing well at normal household water pressure, where standard membranes slow down.

Rating50 GPD*
Size1812 (standard)
TypeULP TFC, tap water
Life2–3 years
FitsStandard 1812 housings

What this membrane does

The membrane is the heart of a reverse osmosis system. Water is pushed through a semi-permeable thin-film layer that lets water molecules pass and sends dissolved solids, salts and metals to the drain. The sediment and carbon pre-filters before it protect it from dirt and chlorine; the post-filter after it polishes taste. Over 2–3 years the membrane slowly loses output and rejection, and replacing it brings the system back to like-new performance.

Key benefits

  • Standard 1812 size fits most under-sink RO membrane housings
  • Ultra-low-pressure design for steady output at normal city water pressure
  • 97.5% stabilized salt rejection (manufacturer data)*
  • Label states: tested and certified by NSF for material safety
  • Factory-sealed and dry-packed for long shelf life
  • Low-cost drop-in replacement

Specifications

Attribute Value
Model Ovay OV-ULP1812-50
SKU MEM-1812-50-U
Rated output 50 GPD (~2.1 gal/hr)*
Stabilized salt rejection 97.5%*
Test conditions 60 psi, 500 ppm feed water
Membrane type Ultra-low-pressure polyamide thin-film composite (TFC)
Water type Tap water (municipal or well)
Size 1.8″ × 12″ (1812)
Replacement interval 2–3 years, or when product-water TDS rises
Pre-treatment Sediment and carbon pre-filters required (chlorine removal)

What a TFC membrane helps reduce

Category Examples Average reduction*
Total Dissolved Solids Overall TDS reading 90–98%
Fluoride Fluoride 85–95%
Heavy metals Lead, copper, chromium, cadmium 90–98%
Nitrates/nitrites Nitrate, nitrite 80–95%
Dissolved salts and minerals Sodium, calcium, sulfate, chloride 90–98%

*Typical ranges for residential TFC membranes. Not a certified claim for each unit. Actual results depend on water pressure, temperature, TDS and pre-filter condition.

About bacteria and microorganisms: this membrane is not sold as a microbiological purifier. Do not use it with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Which membrane do I need?

Your system Size Output Membrane
Standard under-sink RO with tank, 50 GPD 1812 ~2.1 gal/hr MEM-1812-50-U (this membrane)
Standard under-sink RO, 75 GPD 1812 ~3.1 gal/hr TW-1812-75
Countertop RO and under-sink, everyday use 1812 ~4.2 gal/hr TW-1812-100
Watts Premier WP-4V, WP-5 1.8″ × 11-5/8″ ~2.1 gal/hr MEM-1812-50-WP
Kenmore UltraFilter, Whirlpool WHER12/18 1.8″ × 10″ ~2.1 gal/hr MEM-1810-50-KM
RainSoft UF50T / UF50N 1.8″ × 10″ ~2.1 gal/hr MEM-1810-50-RS

Good to know before you buy

What “50 GPD” means. 50 gallons per day is the lab rating at standard test conditions, about 2.1 gallons per hour. At typical home pressure and cooler water, expect less.*

Replacing a 75 or 100 GPD membrane? The drain-line flow restrictor must match the membrane. If you drop to 50 GPD, use a 50 GPD restrictor, or the system will waste more water than it needs to.

Pre-filters protect the membrane. Chlorine destroys TFC membranes. Replace your sediment and carbon pre-filters on schedule, ideally at the same time as the membrane.

Replacing your membrane

  1. Turn off the cold-water feed to the RO system and close the tank valve.
  2. Open the RO faucet to release pressure.
  3. Disconnect the tubing from the membrane housing cap and unscrew the cap.
  4. Pull out the old membrane, using pliers if needed. Note which way it faces.
  5. Insert the new membrane with the end with the two small O-rings first, and push it firmly into place. The black brine seal goes toward the cap.
  6. Replace the cap and tubing, turn the water back on, and check for leaks.
  7. Let the tank fill, then drain it completely. Repeat once and discard the first two tanks.

Compatible systems & replacement membranes

RO systems it fits†

Most 4- and 5-stage under-sink reverse osmosis systems with a standard 1.8″ × 12″ membrane housing, including many APEC, iSpring and Express Water systems. If your current membrane is about 1.8″ × 12″ with a black brine seal on one end, this membrane will fit.

Cross-reference: replaces these 1812 50 GPD membranes†

Brand Part number
FilmTec TW30-1812-50, TW30-1812-50HR
AXEON TF-1812-50, TE-1812-50
Toray / CSM RE1812-50
Vontron ULP1812-50
Pentair TLC-50
Watts W-1812-50
Desal TFM-50

Not compatible with

  • Watts Premier systems with reverse-seal membranes (use MEM-1812-50-WP)
  • Kenmore, Whirlpool and RainSoft systems with 10″ membranes (use MEM-1810-50-KM or MEM-1810-50-RS)
  • Twist-on canister or quick-change membranes (Whirlpool WHEERM, sealed cartridge systems)
  • Tankless and countertop RO systems that need 100+ GPD membranes

Check before you order: measure your old membrane. It should be about 1.8″ wide and 12″ long. If it’s shorter, a twist-on canister, or rated 100 GPD or more for a tankless system, choose a different membrane. Not sure? Send us a photo and we’ll confirm the fit.

Fit questions

Will it replace a FilmTec TW30-1812-50?
Yes. It’s the same 1812 size and 50 GPD rating.

Does it fit my APEC or iSpring system?
Yes, if your system uses a standard 1812 membrane rated 50 GPD. Most 4- and 5-stage systems with a tank do.

Can I put it in a 75 or 100 GPD system?
It fits, but you’ll get less water. Change the drain flow restrictor to 50 GPD so the system doesn’t waste water.

Does it fit my My Water Club countertop RO?
No. Countertop RO systems need a higher-output membrane such as TW-1812-100.

Does it come with a flow restrictor?
No, the membrane only.

*Rated output, rejection, reduction ranges and compatibility are based on manufacturer and industry data; real-world output is usually lower than the rating.

†FilmTec, AXEON, Toray, CSM, Vontron, Pentair, Watts, Watts Premier, Desal, APEC, iSpring, Express Water, Kenmore, Whirlpool and RainSoft are trademarks of their respective owners. Brand names and part numbers are used only to identify compatible products. My Water Club is not affiliated with or endorsed by any of these companies. This is a compatible replacement membrane, not an OEM part.

Additional information

Weight 0.5 lbs
Dimensions 12 × 2 × 2 in

Reviews

There are no reviews yet.

Be the first to review “Universal 50 GPD RO Membrane, 1812 Ultra-Low-Pressure TFC (Ovay OV-ULP1812-50)”