Dual-Stage Whole House Systems — 20″ × 4.5″ on Stand
For all dual-stage 20″ systems on stand: how to install, read the gauge, change the cartridges and order the right replacements.

Check it against this list.
- ✓Two blue sumps under one white steel stand, each taking a cartridge about 4.5″ wide and 20″ long
- ✓A pressure gauge and two red pressure release buttons on top
- ✓1″ brass-threaded inlet and outlet
- ✓A “My Water Club” label on the front edge
Which cartridges are in it?
| Your SKU | Cartridges | Replace | Reorder |
|---|---|---|---|
| WHS-2H-20BB | Your choice | — | Choose cartridges → |
| WHS-2SC-20BB | 1: 5 µm sediment 2: Carbon block (CTO) | 1: Every 6–9 months 2: Every 6–12 months | SED5-20BB → CTO-20BB → |
| WHS-2SB-20BB | 1: 5 µm sediment 2: Coconut carbon block | 1: Every 6–9 months 2: Every 6–12 months | SED5-20BB → CACB-20BB → |
| WHS-2ST-20BB | 1: 5 µm sediment 2: Catalytic carbon | 1: Every 6–9 months 2: About every 6 months on chloramine (6–12 on chlorine) | SED5-20BB → CAT-20BB → |
| WHS-2SR-20BB | 1: 5 µm sediment 2: Iron reduction resin | 1: Every 6–9 months 2: Every 3–6 months | SED5-20BB → IRON-20BB → |
| WHS-2PR-20BB | 1: 5 µm pleated sediment (washable) 2: Iron reduction resin | 1: Rinse as needed · replace every 6–12 months 2: Every 3–6 months | SED5-PLT-20BB → IRON-20BB → |
| WHS-2SD-20BB | 1: 5 µm sediment 2: Scale inhibitor | 1: Every 6–9 months 2: Every 6–12 months | SED5-20BB → SCALE-20BB → |
Note the reading with fresh cartridges while water is running. When it drops noticeably under the same use, the cartridges are loading up — change them, or rinse a pleated cartridge. Change them on schedule anyway: carbon, catalytic carbon and scale cartridges wear out without clogging.
Installing the system
- Pick a level spot indoors, out of direct sun, where it can’t freeze, with a few inches clear below the sumps. It goes on the main line after the meter or the well pressure tank.
- Stand it on the floor, or hang the stand on the wall through the keyhole slots (use screws and anchors rated for the weight of full housings).
- Install a shut-off valve on each side, and ideally a bypass.
- Water flows right to left as you face the front of the system: IN on the right into Stage 1 (sediment), OUT on the left after Stage 2, the housing under the pressure gauge. Check the IN / OUT arrows on the caps.
- Wrap the pipe threads with 3–5 turns of PTFE tape and thread the fittings into the brass inserts snugly — no need to over-tighten.
- Open the inlet valve slowly, press both release buttons to let the air out, check for drips, then open the outlet valve.
Changing the cartridges
- Close the valves on both sides. Put a bucket under the housings.
- Press both pressure release buttons until the hissing stops.
- Loosen each sump with the housing wrench: looking up at the bottom, turn it counterclockwise. Support it with both hands.
- Lift out the old cartridges, rinse the sumps, and wipe the O-rings and grooves clean. Replace any O-ring that is flat, cracked or hard; grease it lightly with food-grade silicone grease.
- Put the new cartridges in the right stage (see the table above): Stage 1 is the right housing, Stage 2 the left one under the gauge. Center each on the post at the bottom.
- Screw the sumps on by hand until snug, then up to a quarter turn with the wrench.
- Open the inlet slowly, bleed the air with the buttons, check for drips, open the outlet, and run cold water for about 5 minutes (carbon) or 2–3 minutes (sediment).
Housings sit under line pressure every day and the plastic slowly fatigues. Replace them about every 5 years, or right away at any crack, crazing or a leak that a new O-ring doesn’t fix. If your water pressure is above 80 PSI, fit a pressure regulator or pressure limiting valve ahead of the system.
Troubleshooting
| Problem | Likely cause | What to do |
|---|---|---|
| Low pressure, gauge reading low | Cartridges clogged | Change the cartridges (or rinse a pleated one). |
| Drip at a sump seam | O-ring twisted, dirty, dry or worn | Depressurize, clean the groove, regrease or replace the O-ring (parts). |
| Chlorine or chlorine-like taste is back | Carbon or catalytic carbon used up | Replace the Stage 2 cartridge. |
| Orange staining is back (iron systems) | Iron resin used up | Replace the iron cartridge (every 3–6 months). |
| Sump won’t unscrew | Still under pressure, or over-tightened | Close the valves, press the release buttons, then use the wrench counterclockwise as seen from below. |
| Crack or leak from a housing body | End of life, frozen or over-pressured | Shut off the water and replace the housing. |
Parts for your system