Dual Housing Kit — 10″ × 4.5″, 1″ NPT
For WHS-2H-10BB and WHS-2H-10BB-G (with pressure gauge): how to choose cartridges, install the kit, change cartridges safely and read the gauge.

Check it against this list.
- ✓Two blue sumps with black caps, each taking a cartridge about 4.5″ wide and 10″ long
- ✓Brass threads inside the 1″ ports
- ✓A red pressure release button on each cap
- ✓A white steel wall bracket across the top
- ✓WHS-2H-10BB-G only: a pressure gauge on the left housing
Which cartridges go in it?
The kit comes without cartridges. Water flows right to left, so Stage 1 is the right housing.
| Your water | Stage 1 (right) | Stage 2 (left) | Replace |
|---|---|---|---|
| Chlorine taste & odor | SED5-10BB | CTO-10BB or CACB-10BB | Every 6–12 months |
| Chloramine | SED5-10BB | CAT-10BB | See the cartridge label |
| Clear-water iron (well) | SED5-10BB | IRON-10BB | See the cartridge label |
| Scale protection | SED5-10BB | SCALE-10BB | About every 6 months |
Any standard 10″ × 4.5″ cartridge fits. Local pickup in San Diego is free.
Specifications
| Cartridge size | Two standard 10″ × 4.5″ |
| Ports | 1″ NPT female, brass inserts |
| Flow | Right to left (IN on the right) |
| Pressure release | Red button on each cap |
| Pressure gauge | WHS-2H-10BB-G: 0–150 PSI, on the left housing |
| Max pressure | 90 PSI · cold water only |
| Size | About 16″ wide × 16″ tall × 8″ deep |
| Housing life | About 5 years |
Installing the kit
- Pick a spot indoors, out of direct sun, where it can’t freeze, with about 12″ clear below the sumps. It goes on the main line after the meter or well pressure tank.
- Hang the bracket on two screws through the keyhole slots, into studs or solid backing. Use screws and anchors suited to your wall; two full housings weigh roughly 25–40 lb.
- Install a shut-off valve on each side, and ideally a bypass.
- Water goes in on the right and out on the left when you face the front. Check the IN / OUT marks on the caps.
- Wrap the pipe threads with 3–5 turns of PTFE tape. Thread the fittings into the brass inserts snugly — no need to over-tighten.
- Fit the cartridges (below), screw the sumps on, then open the inlet valve slowly and check for drips.
Changing the cartridges
- Close the valves on both sides. Put a bucket under the housings.
- Press each pressure release button until the hissing stops.
- Loosen each sump with the housing wrench: looking up at the bottom, turn it counterclockwise.
- Lift out the old cartridges, empty and rinse the sumps, and wipe the O-rings and their grooves clean.
- Check the O-rings. Replace any that are flattened, cracked or hard. Coat them lightly with food-grade silicone grease and seat them without twists.
- Stand each new cartridge in its sump, centered on the post at the bottom. Sediment goes in the right housing.
- Screw the sumps on by hand until snug, then add up to a quarter turn with the wrench.
- Open the inlet valve slowly, press the release buttons to let the air out, check for drips, then open the outlet valve.
- Carbon cartridges: run the cold water for about 5 minutes. Sediment: 2–3 minutes.
With new cartridges and a tap running, note the reading. Check it now and then with the same tap running. A drop of about 10–15 PSI means the cartridges are filling up: change them. A needle near the red zone means your line pressure is too high for the housings: fit a pressure regulator. The small bubble in the gauge window is normal.
Housings sit under line pressure every day and the plastic slowly fatigues. Replace them about every 5 years, or right away at any crack, crazing or a leak that a new O-ring doesn’t fix. If your water pressure is above 80 PSI, fit a pressure regulator or pressure limiting valve ahead of the kit.
Troubleshooting
| Problem | Likely cause | What to do |
|---|---|---|
| Low water pressure | Cartridges clogged | Change the cartridges, sediment first. |
| Drip at a sump seam | O-ring twisted, dirty, dry or worn | Depressurize, clean the groove, regrease or replace the O-ring (parts). Hand-tight plus a quarter turn is enough. |
| Leak at a port | Not enough PTFE tape, or cross-threaded | Shut off, unscrew the fitting, re-tape and thread it in straight. |
| Drip at the gauge | Thread not sealed | Depressurize, unscrew the gauge with a wrench on the square fitting, re-tape and refit. |
| Sump won’t unscrew | Still under pressure, or over-tightened | Close the valves and press the release button first, then use the wrench counterclockwise as seen from below. |
| Crack or leak from the body | End of life, frozen or over-pressured | Shut off the water and replace the housing. |
Parts for your kit
Not sure which cartridges you need? Send a photo to My Water Club support or call (858) 345-7345.